Wednesday, 14 May 2008

ES-U002 Vane Switch - ATEX EExd IIC T4 - Zone 1 Applications

Logo - IATEX

ATEX EExd IIC T4 certified explosion proof vane switch from Euroswitch for use in Zone 1 applications.

This single pole change over switch is actuated by the introduction of a ferrous vane into the switch slot. The switch contains an ATEX EExd IIC T4 reed switch within a body of Engineered Resin that is impervious to most chemicals.

Summary Information

ATEX EExd IIC T4 Vane Switch

ATEX EExd IIC T4 Vane Switch

Body Engineered Resin
Switch Type Single Pole Change Over (S.P.C.O.)
Contacts Rhodium
Cable 2m 3 Core Polyrad
(other lengths available on request)
Sealed Hermetically to IP68
Other Info. Double Insulated
Requires no earth connection
Operating Temp. -40°c to +125°c

Connections

Connection diagram

Ratings

Max. Current Max. Volts Power - Watts
    24v DC 830mA
110v AC 180mA
230v AC   80mA
250v AC
150v DC
20W. VA

Switch Points Diagram

Switch Point Diagram

A ferrous vane, with a minimum size of 75mm x 50mm x 3mm, must pass into the slot within 20mm of the base without touching the sides.

Switch Points at 10mm
Direction On Point Back to Off
X to Y C+22mm C+12mm
Y to X C+18mm B+ 5mm

Dimensions

Dimensions diagram

Certification

ATEX EExd IIC T4

Harmonised European Standards:-
EN 50 014 : 1997
EN 50 018 : 2000
EN 50 281-1-1 : 1998

Certificate No. ISSeP03ATEX081

Certification logos PDF IconDownload pdf certificate